Recall for 3M PELTOR X4 Series Earmuffs

Safety Update Feb 28th 2024

Read below or download 3M's stop use and recall information for the PELTOR X4 Series Earmuffs manufactured between March 2020 - September 2022.


As part of 3M's ongoing commitment to delivering high-quality safety equipment, 3M is issuing a Stop Use and Recall Notice to customers for the 3M™ PELTOR™ X4 Series Earmuffs manufactured between March 2020 through September 2022. 3M has identified that X4 earmuffs manufactured during this time period may develop cracks on the exterior surface of the cups (see Appendix A). All product manufactured in this timeframe must be removed from service even if no cracks are visible on the cups. Please reference the directions below to determine the products that are impacted by this notice and any replacement instructions.

There have been no reports of injuries or accidents associated with this notice.

Cup Model ID Color Material Description Material ID

X4A

GREEN

X4A US PELTOR OVER THE HD EARMUFFS 10/C

7000104073

X4A

ORANGE

3M PELTOR X4A- OR US 10/CS

7100097446

X4B

GREEN

X4B- US EARMUFF BACKBAND 3M PELTOR 10/CS

7100123161

X4P3

GREEN

X4P3E US PELTOR CAP ATTACH EARMUFFS 10/C

7000104078

X4P5

GREEN

3M PELTOR X4P5E US 10/CS

7100097429

X4P5

ORANGE

3M PELTOR X4P5E- OR US 10/CS

7100097526

X4P51

GREEN

X4P51E- US EARMUFF FULL BRIM 3M PELTOR

7100135827


3M's Instructions for End Users:

Step 1: Determine if your earmuff model is affected, locate
the Model ID printed on the outside of the cup (see Figure 1).
Compare the Model ID on the cup to Table 1 (above). If the
Model ID matches any in the table, continue to Step 2. If they do
not match any in the table, your product is not affected by this
Notice.

Step 2: Locate the manufacturing (mfg) date (MM/YYYY)
printed on the outside of the cup (see Figure 1). If the earmuff
manufacture date is on or between 03/2020 and 09/2022, your
product is affected. Continue to Step 3.

Step 3: To coordinate the return of your affected product(s)
for replacement visit 3m.com/PELTOR-X4-Replace to view
the details and complete the electronic intake form.


Figure 1: Model ID and Mfg Date

Appendix A: Examples of cracking